70-24157-03 Inducer Motor Blower for Rheem
PRYSM
v.option1 == myState.option1 && v.option2 == myState.option2 && v.option3 == myState.option3)[0].variantPrice || 'selected options not available'">$149.59
Description
Description
- Cross Reference Information
70-24157-03, AS-67915-02, 2638751, 00-81R02QJAA, 7121-11559, 117847-00, J238-150-15165, 7058-1406, J238-150-1533, J2381501533, 117847-07, 11784707, 117847-7, 1178477, J238-150-1533, J2381501533, 11710401, 117104-01, 117104-04, 17104-01, 30-6631, 17104-01, 1710401, 300792F, 300792F7, 66838, 7021-11559. - Quality you can Trust! All Snap Products are made with premium materials and are tested so they last.
- Compatible with the following Furnace brands: Rheem
- UPC #: 810019171543
- ASIN #: B077BJ7VDR
Installation Instructions
Installation Instructions for 70-24157-03
- Shut off power to furnace
- Slide upper access panel to remove
- Detach exhaust vent tube from outlet part of inducer
- Detach black vacuum tube form pressure switch
- Use flat head screwdriver to detach mounting bracket pressure switch screws
- Move bracket out of the way
- Note the motor wires and disconnect them
- Unthread assembly mounting screws on old motor
- Carefully remove old motor and set aside
- Take new SNAP Supply Inducer Motor out and install it
- Replace screw to secure motor into place
- Connect wires
- Reposition the pressure switch and mounting bracket
- Replace pressure switch screws
- Connect new vacuum tube to pressure switch
- Position the exhaust bent tube onto outlet port of the new motor
- Replace access panel
- Turn power switch on & done!
|
Tools Needed
|